Meters
Complete BTU (Energy) Metering System requires a flow meter, purchased separately. Temperature sensor thermowells and mounting hardware purchased separately. .
(Suitable for F-1100-10-B2-1221)

MÁY ĐO HỆ THỐNG-10 BTU

Máy đo BTU System-10 là một thiết bị dựa trên bộ vi xử lý có độ chính xác cao được thiết kế để cung cấp đầy đủ dữ liệu về năng lượng, lưu lượng và nhiệt độ ở cả màn hình LCD phía trước và qua giao diện mạng nối tiếp tùy chọn. System-10 cũng có sẵn với các tín hiệu đầu ra tương tự tùy chọn cho năng lượng, lưu lượng và nhiệt độ. System-10 là lựa chọn lý tưởng để kết nối mạng với các hệ thống điều khiển với sự sẵn có của BACnet ® , MODBUS ® , LonWorks ® , Johnson Controls-N2 ® , thẻ giao diện Siemens-P1 ® .

Các ứng dụng tiêu biểu

Hệ thống nước lạnh, nước nóng và nước ngưng tụ cho:

  • Hóa đơn thuê văn phòng thương mại
  • Giám sát nhà máy trung tâm
  • Giám sát khuôn viên trường đại học
  • Phân bổ chi phí năng lượng thể chế
  • Đánh giá hiệu suất/hiệu quả
  • Hiệu suất hợp đồng giám sát năng lượng
  • Giám sát thu hồi nhiệt đồng phát

Trách nhiệm nguồn duy nhất

Một nhà sản xuất chịu trách nhiệm sản xuất, tính tương thích của các thành phần và hiệu chuẩn của toàn bộ hệ thống đo lường BTU. ONICON cam kết cung cấp các hệ thống có độ chính xác cao và đáng tin cậy đảm bảo cài đặt thành công.

NIST Traceable Calibration với chứng nhận

Hoàn thành hiệu chuẩn toàn hệ thống cho toàn bộ hệ thống đo lường BTU cho từng ứng dụng cụ thể với chứng nhận hiệu chuẩn.

Cảm biến nhiệt độ trạng thái rắn chính xác

Được hiệu chỉnh tùy chỉnh và khớp với độ chính xác cao hơn ±0,15° F từ 32-200° F.

Cài đặt và vận hành đơn giản

Được lập trình tại nhà máy và sẵn sàng sử dụng khi giao hàng, tất cả dữ liệu quy trình và chức năng lập trình đều có thể truy cập thông qua màn hình và bàn phím phía trước.

Giao diện người dùng dễ vận hành

Màn hình điều khiển bằng menu và bàn phím màng giúp xem dữ liệu dễ dàng và đơn giản hóa việc lập trình lại trường khi cần thiết.

Truyền thông nối tiếp tương thích mạng

Thẻ giao tiếp tùy chọn cung cấp dữ liệu năng lượng, lưu lượng và nhiệt độ hoàn chỉnh thông qua một kết nối mạng duy nhất. Có sẵn với các thẻ giao diện BACnet ® , MODBUS ® , LonWorks ® , Johnson Controls-N2 ® và Siemens-P1 ® .

Đồng hồ đo lưu lượng chính xác cao

Mỗi Máy đo System-10 BTU hoạt động với các máy đo lưu lượng dòng xoáy, siêu âm, điện từ, kẹp và chèn của ONICON.

 

100% USA Origin

Onicon Vietnam

Model: FT-3210-13111-1021-101
Flow Sensor
In-line Flow Sensor 10″. CS body with PTFE liner, 300 # flanges and 3, 316 SS electrodes. Advanced transmitter with  (1) AO, (2) DO,  no serial comm., IP 67 painted aluminum enclosure & input power TBD.  Integral mount.
Electromagnetic inline flow meter suitable for use in DW, CHW, CW and HHW applications.

100% USA Origin

Onicon Vietnam

Model: FT-3210-13111-1021-101
Flow Sensor
In-line Flow Sensor 10″. CS body with PTFE liner, 300 # flanges and 3, 316 SS electrodes. Advanced transmitter with  (1) AO, (2) DO,  no serial comm., IP 67 painted aluminum enclosure & input power TBD.  Integral mount.
Electromagnetic inline flow meter suitable for use in DW, CHW, CW and HHW applications.

100% USA Origin

Onicon Vietnam

Model: F-1100-10-C3-1221
Flow Meter

100% USA Origin

Onicon Vietnam

Model: F-1100-10-E5-1221
Flow Meter
1.25 – 72″
Single turbine insertion flow meter with freq, analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine flow meter suitable for use in CHW and HHW applications. Complete codification is based on pipe size range, pipe material and fluid temperature.

100% USA Origin

Onicon Vietnam

Code: F-1100-11-D4-1221
1.25 – 72″
Flow Meters
Single turbine insertion flow meter with freq, iso analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine flow meter suitable for use in CHW and HHW applications. Complete codification is based on pipe size range, pipe material and fluid temperature.

100% USA Origin

Onicon Vietnam

Model: F-1100-10-D4-1221
Flow Meters
1.25 – 72″
1.25 – 72″ Single turbine insertion flow meter with freq, analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine flow meter suitable for use in CHW and HHW applications. Complete codification is based on pipe size range, pipe material and fluid temperature.

100% USA Origin

Onicon Vietnam

Code: F-1100-11-D4-1221
1.25 – 72″
Flow Meters
Single turbine insertion flow meter with freq, iso analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine flow meter suitable for use in CHW and HHW applications. Complete codification is based on pipe size range, pipe material and fluid temperature.

100% USA Origin

Onicon Vietnam

Code: FT-3210-11511-1021-101
Flow Meters

100% USA Origin

Onicon Vietnam

Code: FT-3212-11511-1021-101
Flow Meters

100% USA Origin

Onicon Vietnam

Code: FT-3216-11511-1021-101
Flow Meters

100% USA Origin

Onicon Vietnam

Code: FT-3204-11511-1021-101
Flow Meters

100% USA Origin

Onicon Vietnam

Code: FT-3220-13111-2121
Flow Meters

100% USA Origin

Onicon Vietnam

Code: FT-3220-13111-2121-101
Flow Meters

100% USA Origin

Onicon Vietnam

Code: F-11XX-11-00-3229
Flow meter
75 or 1″
75 or 1″ line size with freq, iso analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine, in-line flow meter suitable for use in CHW and HHW applications.

100% USA Origin

Onicon Vietnam

Code: F-3500-11-F6-1211
Flow Meters

100% USA Origin

Onicon Vietnam

Code: F-1100-10-B2-1221
Flow Meters
1.25 – 72″
Single turbine insertion flow meter with freq, analog and scaled pulse output, plated brass stem, NEMA 4 enclosure and 10′ PVC cable.
Single turbine flow meter suitable for use in CHW and HHW applications. Complete codification is based on pipe size range, pipe material and fluid temperature.

100% USA Origin

Onicon Vietnam

Code: SYS-10-1100-01O1
Meters
Complete BTU (Energy) Metering System requires a flow meter, purchased separately. Temperature sensor thermowells and mounting hardware purchased separately. .
(Suitable for F-1100-10-B2-1221)

100% USA Origin

Onicon Vietnam

Code: F-2604-324-1301
Flow Meters

Gói phần cứng cài đặt

Thermowells và phần cứng cài đặt liên quan được cung cấp cùng với hướng dẫn cài đặt để đảm bảo cài đặt không có lỗi và hiệu suất hệ thống chính xác.

 

Sản phẩm cùng loại
0
Zalo
Hotline